DuraVent DuraTech 6 Diameter Stainless Steel 12 Pipe Length 6DT

DuraVent DuraTech 6 Diameter Stainless Steel 12 Pipe Length 6DT

4.5
(625)
Write Review
More
$ 60.50
Add to Cart
In stock
Description

All-fuel, double-wall chimney system. UL 103 HT and ULC S604 With a Thermal Tech blanket insulation encased between dual walls, DuraTech offers optimum safety and performance. It keeps the outer wall of the chimney cool while ensuring high flue gas temperatures for optimum draft performance. The inner wall is 25% thick
All-fuel, double-wall chimney system. UL 103 HT and ULC S604 With a Thermal Tech blanket insulation encased between dual walls, DuraTech offers optimum safety and performance. It keeps the outer wall of the chimney cool while ensuring high flue gas temperatures for optimum draft performance. The inner wall is 25% thicker than competitive chimneys for an extra margin of safety. No locking bands or mechanical fasteners are required. DuraTech’s sleek 1″ wall design provides for easy installations through 16″ on-center framing. For tight installations, a Reduced Clearance Square Ceiling Support Box is available (6 diameter DuraTech only). Designed for normal, continuous operation at 1000°F flue gas temperatures, DuraTech is subjected to rigorous and stringent high-temperature requirements of the UL standard, including one hour at 1400°F, plus three ten-minute chimney fire test at 2100°F. Product Details Model  DuraTech 6 Part no. 6DT-12SS Inner Diameter, A 6 inch Outer Diameter, B 8 inch Pipe Length 12 inch Inner Wall Material 0.020” 430 Stainless Steel Outer Wall Material 0.016” 430 Stainless Steel Chimney Pipe Dimension   To calculate installed length of 5”, 6”, 7”, or 8” DuraTech Chimney, subtract 1 1⁄4” from each joint overlap of chimney pipe. Allow a minimum of 2” air space tocombustibles when installing DuraTech Chimney. Specifications Applications DuraTech is a double-wall, all-fuel chimney system for use with wood stoves, fireplaces, furnaces, boilers, ranges, water heaters, or other appliances fueled by wood, oil, coal, or gas, and zero-clearance fireplaces that are factory-built. Materials and Construction 5”, 6 7, or 8” diameter pipe features an inner wall of .020” 430 stainless steel. Outer wall options of .016” 430 stainless steel or .021” galvalume steel. Refractory insulation is encased between walls. Stainless steel end rings seal the pipe. DuraTech features lightweight insulation, twist-lock fittings, support boxes with factory-installed starter sections, elbows with 360° swivel base, select black finish pipe lengths, five-foot length pipe sections, and adjustable pipe lengths. Clearances 2” clearance to combustibles. Shrouds Shroud specs allow the installer to create a UL-listed shroud to hide the termination at the top of the chase for the safest installation. Features A wide variety of diameters is available. Most lengths are available. Twist-lock fittings. No locking bands or mechanical fasteners are required. Made by the industry leader with over 50 years of manufacturing. Thermal Tech blanket insulation encased between two walls keeps the outer wall cool while ensuring high flue gas temperatures for optimum draft performance. Available with stainless or galvalume outer walls. Limited Lifetime Warranty The best Warranty in the industry. 15 years 100%, 15 years, and up 50%. Gives the installer and homeowner the greatest peace of mind in a quality installation. Typical Chimney Installation Refer to our Typical Installation to select the appropriate component parts for your installation.  DVL/DuraBlack Chimney Adapter must be used when connecting DVL pipe to a Ceiling Support Box or Finishing Collar. When connecting the DuraBlack pipe, a DVL/DuraBlack Chimney Adapter, DuraBlack Slip Connector, or Snap-Lock Adapter must be used. Wall Thimble must be installed with an appropriate length of chimney pipe for all horizontal through-the-wall installations. To accommodate thicker walls, the telescoping pieces of the Wall Thimble can be separated, and a field-fabricated extension may be installed. Attic Insulation Shield must be used in all installations that pass through an attic, regardless of whether the attic is insulated or not. Firestop Radiation Shield must be used when a chimney passes through a floor or ceiling without a support box.   Downloads Typical Chimney Installations Product Catalog Product Installation Instructions

6 Trim Collar For Roof Support 0-3/12 DuraVent DuraTech Chimney 6DT-RSTC3

Monsma 6DT-ST STANDARD TEE W/CAP- GA

DuraVent 6DT-F12 6 DuraTech Adjustable Roof Flashing 7/12 - 12/12

Duravent 6Dp-E30kss 6 Inner Diameter - Stainless Steel

DuraVent 6DT-LB 6 DuraTech Locking Band

Almost never undersold. Let us quote your pipe. Our NFI Master Hearth Certified Technician will evaluate your pipe installation project and give you a customized quote. Call or e-mail us today! DuraVent 6 DuraTech Adjustable Wall Strap - Stainless Steel - 9468SS Use in interior or exterior installations to support and stabilize the chimney.

DuraVent 6DT-WSSS DuraTech Adjustable Wall Strap - 6, Stainless Steel

6 DuraVent DuraTech Attic Insulation Shield 6DT-IS

DuraVent 6DT-XWS DuraTech 6 and 8 Adjustable Extended Wall Support

6 DuraTech Stainless Steel Tee with Cap - 6DT-STSS

6 DuraVent DuraTech Galvanized 7/12-12/12 Flashing 6DT-F12

DuraVent DuraTech 6 Diameter Galvalume Steel 12 Pipe Length 6DT